Guide: Steam boilers are special equipment and belong to pressure vessels, so they are strict from manufacturing to installation and acceptance. Its normal operation is directly related to property and life safety, so the normal operation of steam boilers is particularly important.
When we use a steam boiler, we need to install a water level meter to check the water volume change in the boiler body. The water level meter is generally equipped with an electronic water level meter or a water level automatic display instrument. When the measurement value of the water level meter is inaccurate, we should carry out in time Adjustment.
The water level gauge of the steam boiler needs to be cleaned regularly to ensure that the water level scale cleaning is visible. If the corresponding maintenance is not carried out regularly, the water level gauge will be prone to rust and die, and the connecting pipe of the water level device is also prone to deposit scale, produce impurities, and affect the normal water level. Happening. So, how to deal with the failure of the steam boiler water level gauge?
1. When the water level gauge is damaged, we must first close the water level valve and replace it with a new one.
2. When the pressure cannot rise, it may be because the pressure switch is malfunctioning or the pressure switch connecting pipe is blocked. We need to replace or clean it in time.
3. When the scale value of the water level gauge displays abnormally, for example, it has not been raised or there is no water level value, we need to consider whether the boiler's blowdown valve is open, and if it needs to be closed.
When we use a steam boiler, we need to install a water level meter to check the water volume change in the boiler body. The water level meter is generally equipped with an electronic water level meter or a water level automatic display instrument. When the measurement value of the water level meter is inaccurate, we should carry out in time Adjustment.
The water level gauge of the steam boiler needs to be cleaned regularly to ensure that the water level scale cleaning is visible. If the corresponding maintenance is not carried out regularly, the water level gauge will be prone to rust and die, and the connecting pipe of the water level device is also prone to deposit scale, produce impurities, and affect the normal water level. Happening. So, how to deal with the failure of the steam boiler water level gauge?
1. When the water level gauge is damaged, we must first close the water level valve and replace it with a new one.
2. When the pressure cannot rise, it may be because the pressure switch is malfunctioning or the pressure switch connecting pipe is blocked. We need to replace or clean it in time.
3. When the scale value of the water level gauge displays abnormally, for example, it has not been raised or there is no water level value, we need to consider whether the boiler's blowdown valve is open, and if it needs to be closed.